Specification of

Features SD 320 Con

Min/Max Value Memory the highest and lowest measured value is saved

Auto Hold freeze and display measurement

Auto Power Off if unused, the meter automatically switches off after a selected period (0 to 120 min, or deactivated)

Low Battery Display "BAT"

Automatic temperature compensation the Us conductivity depends strongly on temperature, each conductivity value is only valid at the corresponding temperature. Therefore the device supports temperature compensation, i.e. referring the conductivity to a reference temperature (selectable: 20 ° C or 25 ° C).

Salinity Salinity measurement means the sum of amount of all dissolved salts in water. The unit is g/kg.

Measurement of TDS (total dissolved solids) TDS means the mass concentration of dissolved in a liquid medium. The unit is mg/l.
Delivery Content

Order Code: 72 47 00 SD 320 Con (SET 1)
instrument, batteries, conductivity cell LC 12 (measuring range 0 – 200 mS), manuals, guarantee sheet in case

Order Code: 72 47 20 SD 320 Con (SET of 2) instrument, batteries, conductivity cell LC 4 (measuring range 0 – 1000 mS), manuals, guarantee sheet in case
Assessories
Order code Article
19805040 Conductivity cell LC 12,
measuring range 0 – 200 mS
19805040 Conductivity cell LC 4,
measuring range 0 – 1000 mS
72 22 50 Calibration solution 1413 µ S/cm
72 46 20 300 USB cable,
for connection to a computer
72 46 25 GSOFT 3050 data transmission
software with the logger for the setting,
reading and printing of stored data
72 50 60 Case with foam inlet
Measuring ranges
Number 5
Smallest range 0, 000 ... 5, 000 S/cm or ¼ 0, 0 ... 500, 0 ¼ S/cm **
biggest range 0 ... 5000 ¼ S/cm * or 0 ... 1000 mS/cm **

Resistivity

0,005 ... 500.0 kOhm/cm (depends on cell constant)
TDS

0 ... 5000 mg/l (depends on cell constant)
Salinity

0.0 ... 70.0 (g salt/kg water equals PSU = Practical Salinity units)
Temperature

– 5.0 ... + 100.0 ° C, Pt1000 or NTC (10 kOhm)

The supported cell constants.php
4, 000 ... 15, 000/cm-1 0, 4000 ... 1, 5000/cm-1 0, 04000 ... 0, 15000/cm-1 0, 004000 ... 0, 015000/cm-1
Accuracy

Conductivity

± 0.5% of reading
± 0.1% FS (depends on electrode)
Temperature of ± 0, 2 ° C (-5, 0 ... + 100, 0 ° C)
Connection

Conductivity, Temperature

1 x 7 pole bayonet connector for the connection of different measuring cells

Supported temperature sensors
Pt1000 or NTC (10 k)
Interface/Ext. supply

4-pole bayonet connector for serial interface and supply (with accessory USB 300)
Display

two 4.5-digit seven-segment – display (15 mm and 12 mm)

Protectionclass

IP67 (housingandconnections)

Dimensions

160x86x37mm (W xHxD) incl. protection cover

Weight

250 g incl. battery and protective armouring
Housing

impact resistant PA 6 G B30 housing with pop-up clip
Power supply

2 x AAA-battery (included) power consumption: < 6, 25 mA
Battery life of 160 hours

depends on the cell constant of the used electrodes
* the cell constant 0.01/cm
** cell constant 0.1 ... 1.2/cm

Untuk pelayanan terbaik hubungi:

Ibu WATY

Mobile: 081376851098

____________________________________________________________

CV. KARUNIA MAKMUR PERSADA

KOMPLEK RUKO TRITURA VISTA  BLOK A ,  JL.  M. BASIR NO. A- 6

PANGKALAN  MASYHUR, MEDAN   20143

TELP: 081376851098, 061-42779826, 42779836  Fax: 061-42779826

Email: wati@karuniamakmurpersada.com, karuniamakmur@yahoo,com

Website :       karuniamakmur.indonetwork.co.id

                       www.coolboxdelta.com

 

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot